Determination of inorganic species of Sb and Te in cereals by hydride generation atomic fluorescence spectrometry
2011
A non-chromatographic fast, sensitive and easy method has been developed for the determination of Sb(III), Sb(V), Te(IV) and Te(VI) in cereal samples. The procedure is based on ultrasound assisted extraction and determination by hydride generation atomic fluorescence spectrometry (HG AFS). Preliminary studies were made in order to get the best extraction efficiency using 1 mol L-1 phosphoric acid, 1 mol L-1 nitric acid, aqua regia, 1 mol L-1 sulfuric acid and 6 mol L-1 hydrochloric acid. The extraction with aquaregia showed a clear interconversion of the species during the process, being H2SO4 the best extractant with efficiencies greater than 90% from the total content of Sb and Te quantif…
Development of ultrasound-assisted digestion methods for the determination of toxic element concentrations in ash samples by ICP-OES
2011
The present thesis introduces several ultrasound-assisted digestion methods developed for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry (ICP-OES). Ultrasound-assisted digestion is a quite new technique used for sample pre-treatment purposes, especially in difficult sample matrixes. Elements determined are As, Ba, Co, Cr, Cu, Ni, Pb, Sb, Sr, V, and Zn. Most of the elements determined exist at a trace or ultra trace level in ashes and most are potential risks in the environment or human body even at low concentrations. Most of the selected elements can be determined directly by ICP-OES, but for the determination of…
The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry (H…
2011
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated boric acid …